You are using a version of Internet Explorer (version 8 and / or older) or the compatibility mode, which does not support some functionalities of the site you're viewing. This page can be displayed correctly you therefore may not. In order to use the full functionality of the site is a current Internet Explorer or another browser (eg: Google Chrome, Firefox) necessary.

Turb® 550

WTW Turb® 550 Lab turbidity meter

Turbidity meters for all nephelometric measurements in the lab and in drinking water analytics of 0.01 - 1000 NTU according to DIN ISO 27027 / US EPA 180.1

  • Highly precise AMCO Clear® standards
  • AQA
  • Flow-through measurement

The lab turbidity meters of the Turb® 550 series with IR lamp as per DIN ISO or Tungsten-halogen lamp as per US EPA for nephelometric measurements with automatic 1-3 point calibration and calibration interval monitoring with protocol for the AQS. User guidance and quick instructions on the meter ensure user-friendly measurements and calibration. The calibration is conducted with highly precise AMCO Clear® polymer standards, called a secondary standard for drinking water as per DIN ISO 27027, EN ISO 7027 or approved as primary standards as per US EPA (0.02 – 10.0 – 1000 NTU). The analytical quality assurance (AQA) takes place via an adjustable calibration interval and a calibration protocol.

AMCO Clear® Standards

Compared to Formazine, polymer calibration standards offer a much higher accuracy and stability without drifting, which increases the measuring accuracy even more:

  • Manufacturing tolerance of only ±1% for highest result accuracy
  • Long-term stable particle distribution and size
  • No health hazard
  • Easy to dispose of
  • N.I.S.T. traceability

For continuous measurements, there is an attachment for flow-through available. The measurement data can be sent to a PC or a printer timer-controlled via the RS232 interface.

Variations

Model Description Order no.
Turb® 550 IR Turbidity meter with infrared LED: nephelometric according to DIN ISO with ACMO Clear® Calibration standards 600110
Turb® 550 Turbidity meter with tungsten lamp: nephelometric according to US EPA 180.1 with ACMO Clear® Calibration standards 600100

Technical Data

Measuring ranges NTU 0 … 1000 / 0-1000
FNU 0 … 1000 (IR)
Resolution (NTU) 0.01 for range 0.00 … 9.99
0.1 for the range 10 … 99.90
1 for range 100 … 1000
Accuracy (NTU) ± 0.01 NTU or ± 2% of measured value
Reproducibility 0.01 NTU or ±1% of measured value
Cuvette size 28x70 mm, 25 ml sample volume
Power supply Power cable 100-240 VAC ±10%

Matching and supplemental products

Accessories

Model Description Order no.
Cal.Kit P Turb®550 IR/T Calibration set for Turb® 550 IR/T (0.02-10-1000 NTU) incl. marking rings 600542
Cell Turb/SET Empty cuvette set 3 ea. for Turb® 550/555 devices 600601
D-Turb Flow vessel for Turb® 550/555 devices, pressure-free 600600
Lamp Turb® 550-IR Preadjusted replacement lamp IR for Turb® 550 IR 600607
Lamp Turb® 550/555-WL Preadjusted replacement lamp tungsten-halogen for Turb 550 and Turb 555 (white light/T) 600603

Downloads

Are you interested
in signing up for the free
WTW newsletter?
Newsletter
registration

WTW Newsletter Registration

Any Question?
We advise
you gladly!
Contact

WTW Contact