You are using a version of Internet Explorer (version 8 and / or older) or the compatibility mode, which does not support some functionalities of the site you're viewing. This page can be displayed correctly you therefore may not. In order to use the full functionality of the site is a current Internet Explorer or another browser (eg: Google Chrome, Firefox) necessary.

Multi-parameter monitor MULTILINE 1000

WTW drinking water measurement multi-parameter system MULTILINE 1000

Flexible measuring system with very price/performance ratio for drinking water analytics - up to 16 freely selectable sensors can be connected

  • For immediate use: Premounted on wall mounting plate
  • User-friendly by intuitive menu guiding and large touchscreen
  • No use of chemicals - environmentally friendly and cost-saving

The multi-parameter system MULTILINE 1000 to measure pH, ORP, oxygen, conductivity, turbidity, free or total chlorine - simply connect - done! The measuring results can be transferred out conveniently via digital interfaces (RS 232/RS 422/RS 485), analog power outputs (4 x 0(4) … 20mA) or 4 potential-free relay outputs (for limit value/alarm function). To monitor the inflow, flow measurement is also available.

Variations

Model Description Order no.
MULTILINE 1000 230VAC Multi-parameter monitor to connect up to any 16 sensors, power supply230 VAC 480200
MULTILINE 1000 115VAC Like the MULTILINE 1000 230VAV, but with power supply 115 VAC 480201

Technical Data

Power supply 115/230 VAC
Ambient temperature -10 … + 55°C
Data memory Internal, approx. 50.000 Wete, incl. date and time
Dimensions 239 mm x 240 mm x 125 mm (HxWxD)
Housing Aluminum housing, protection class IP 65
Measuring range pH 0,00 … 14.00 pH
Measuring range ORP - 2000 … + 2000 mV
Measuring range oxygen 0.00 … 20.00 mg/l
0.0 … 200.0 %
Measuring range conductivity 100 µS/cm … 20 mS/cm
Measuring range chlorine 0.00 … 2.00 mg/l

Accessories

Model Description Order no.
MLU-2210 Measuring module internal pH (PCB to be installed into MULTILINE 1000) to feed the measuring signal into the MULTILINE 1000 monitor via a BUS cable) 190026
MLU-2215 Measuring module internal ORP (PCB to be installed into MULTILINE 1000) 190051
MLU-2260 Measuring module internal chlorine amperometric (PCB to be installed into MULTILINE 1000) 290051
MLU-2220 E Measuring module external conductivity (external PCB with metal housing to feed the measuring signal into the MULTILINE 1000 monitor via a BUS cable) 390025
MLU-2220 Measuring module internal (PCB to be installed into MULTILINE 1000) 390026
MLU-2000 E-C External module for 4 x 0/4–20 mA outputs 480210
MLU-2260 E-C External module for 1 x 0/4–20 mA input into MULTILINE 1000 of the Turb 2000 series or Chlorine 3000 480262
FCML 412 pH-Wert independent chlorine electrode (1 m cable) as per the electro-chemical principle, suitable measurement of free clorine in drinking water and pool water. Measuring range: 0-2 mg/l, pH range 4–9 201185
TCML Chlorine electrode (1 m cable) as per the electro-chemical principle, suitable for measurements of total chlorine in drinking water and pool water. Measuring range: 0-2 mg/l 201190
FCML 68 Chlorine electrode (1 m cable) as per the electro-chemical principle, suitable for measurements of free chlorine in drinking water and pool water. Measuring range: 0–2 mg/l, pH range 6–8 201195
ZBK-FCML 412 Maintenance set for chlorine sensor FCML 412: 100 ml electrolyte, 1 replacement cap 205247
ZBK-FCML 68 Maintenance set for chlorine sensor FCML 68: 100 ml electrolyte, 1 replacement cap 205248
ZBK-TCML Maintenance set for chlorine sensor TCML: 100 ml elekcrolyte, 1 replacement cap 205249
SenTix® ML 70 pH single-rod measuring chain with glass shaft, glass etched ring diaphragm, gel electrolyte, S7 screw plug head, PG 13.5 thread 104100
SenTix® MLORP ORP single-rod measuring chain with glass shaft, glass etched ring diaphragm, gel electrolyte, platinum head, S7 plug head; PG 13.5 thread 104150
TFK 5000 Temperature sensor with 1 m cable, Pt 1000 for Multiline 1000 and monitor pH 5000; open cable ends 104151
AK-S7/1 Coaxial cable ORP/pH-free end/S7 connector, 1 m. For MULTILINE 1000, measuring panel included in the delivery 108150
TEP 10 Trace Technical buffering solution, 1 bottle with 1 l : pH 10,01 108703
TPL 4 Technical buffering solution, 1 bottle with 250 ml: pH 4.01 108800
TPL 7 Technical buffering solution, 1 bottle with 250 ml: pH 7.00 108802
TPL 10Trace Technical buffering solution, 1 bottle with 250 ml: pH 10,01 108805
PL 4 Standard (DIN/NIST) buffering solution, 1 bottle with 250 ml: pH 4,006 /4,01 109110
PL 7 Standard (DIN/NIST) buffering solution, 1 bottle with 250 ml: pH 6,865 /6,87 109120
PL 9 Standard (DIN/NIST) buffering solution, 1 bottle with 250 ml: pH 9,180 /9,18 109130
RH 28 ORP buffering solution pH 7, UH = 427 mV (CH), 1 bottle with 250 ml 109740
E-SET Trace Calibration set, 6 bottles with 50 ml calibration and control standard ea., KCl 0,01 mol/l, 1413 μS/cm at 25 °C, traceable to PTB/NIST. 300572
LR ML Conductivity measuring cell, 1 m fixed cable, 2 graphite electrodes; - 5–80 °C, Polysulfon shaft, measuring range: 100 μS/cm – 20 mS/cm, temperatur measurement with Pt 1000; PG 13.5 thread 301150
Oxi ML 41 module Measuring module for the measurement of dissolved oxygen to build up the drinking water measuring panel with the monitor MULTILINE 1000. Includes, the sensor, measuring module, accessories kit and flow fitting 201930
Oxi ML 41 Oxygen probe (1 m cable) measuring range: 0-20 mg/l or 0-200 %; electro-chemical sensor. Temperature range: -5 – 45°C, with temperature sensor Pt 1000; open cable ends 201931
ZBK-Oxi ML 41 Accessories kits for the oxygen electrode Oxi ML 41. Includes 3x replacement membrane heads and 6 vials of electrolyte 202300
DFL-G1/4 Flowmeter with frequency output, PVC, DN10 480265
D-CL Flow fitting for chlorine sensors FCML 412, FCML 68 and TCML. 1 installation point, screw connection DN 10 201150
D 220 Skewed flow fitting to hold conductivity or oxygen electrodes with PG 13.5 thread. Material: PVC 401993
D 222/3 Flow fitting to hold pH, conductivity, ORP electrodes with PG 13.5 thread. Material: PVC 401995
ZBS DW-Panel Small parts set: 3 RV seals, 4 screw clamps for MULTILINE 1000, 1 blind plug, 4 blind washers PG 7 and 4 blind discs PG 9 for DW panel 860100
Pr-DN10 Pressure reducer input pressure max. 16 bar, output pressure 1.5-6 bar, adjustable. DN10, for DW panel with MULTILINE 1000 904000
Do-DN10 Dosing ball valve to regulate the flow volume of 0–90 l/min, DN10, PVC 904005
Cal/C Calibration console for DW panel, PVC white 907010