You are using a version of Internet Explorer (version 8 and / or older) or the compatibility mode, which does not support some functionalities of the site you're viewing. This page can be displayed correctly you therefore may not. In order to use the full functionality of the site is a current Internet Explorer or another browser (eg: Google Chrome, Firefox) necessary.

Determine biological degradability OxiTop ® Control S/A

WTW benchtop meter OxiTop® Control S/A

OxiTop® Control meter to determine biological degradability according to OECD/microbiology – lab procedure according to DIN ISO 29 408 / ISO 9408 / OECD 301 F

  • Easy handling for secure results
  • Flexible use for different volumes and temperatures
  • Graphic evaluation in the controller for process monitoring

The determination of biological degradability must be ensured before using "new" chemicals for the first time; not for reasons of environmental protection, but also to minimize disposal costs.

The prepared sample and a blind sample are stirred in a closed bottle at a constant temperature for 28 days.

The generated CO2 is removed from the headspace by means of an absorber so that the generated vacuum pressure can be used as a measure for the biodegradability.

The continuous recording of the measured values in the OxiTop®-C ensures the required documentation.

The measuring bottles and the adapter can be autoclaved at 121 °C.

Variations

Model Description Order no.
OxiTop® Control S 6 Set with 6 measuring points, OC 110 208196
OxiTop® Control S 12 Set with 12 measuring points, OC 110 208198
OxiTop® Control A 6 Set with 6 x 1.0 l bottles, OC 110 208220
OxiTop® Control A 12 Set with 12 x 250 ml, OC 110 208222
OxiTop® OC 110 Controller 208207

Technical Data

OC 110
Measuring range BOD standard and routine 0 to 4000 mg/l BOD
BOD special 0 to 400.000 mg/l BOD
pressure 500 to 1350 hPa
Data sets (depending on measuring interval) 180 to 360 data sets per head
Measuring interval 0.5 h to 99 days
OxiTop®-C, OxiTop®-C/B
Measuring range 500 to 1350 hPa
Accuracy ±1 % v. Mw. ± 1hPa

Accessories

Model Description Order no.
OxiTop® OC 110 Controller 208207
OxiTop®-C 6 6 Measuring heads 208822
OxiTop®-C 2 2 measuring heads 208823
OxiTop®-C Measuring head 208830
OxiTop®-C/B Measuring head biogas 208831
AK 540/B Interface cable 902842
OxiTop® AD/SK Adapter/screw quiver for GL 45 thread 209016
OxiTop® AD Adapter 209017
OxiTop® SK Screw quiver 209018
NKI 500 CO2Absorber 209142
VS 45 Screw connection OxiTop® AD 209500
DI 45 Seal GL45 209501
ST-OxiTop® Storage rack for heads 209010
Batt/OxiTop® Battery cells 209012
RST 600 Stirrer 209120
REF 600 Stirrer remover 209130
NHP 600 Sodium hydroxide pads 209140
NTH 600 Nitrification inhibitor 209331
OxiTop® PM Calibration tablets 209333
OxiTop® PT Leakage test material 209334