You are using a version of Internet Explorer (version 8 and / or older) or the compatibility mode, which does not support some functionalities of the site you're viewing. This page can be displayed correctly you therefore may not. In order to use the full functionality of the site is a current Internet Explorer or another browser (eg: Google Chrome, Firefox) necessary.

OxiTop ® Control AN measuring system

WTW's OxiTop® Control meter for biogras measurement/microbiology (aerobic/anaerobic measuring)

OxiTop® Control meter for biogras measurement/microbiology (aerobic/anaerobic measuring)

  • Comfortable and accurate measurements of the biogas rate
  • Targeted manipulation possible due to special measuring bottles
  • Safety by warning pressure function

One of the main applications is the testing of fermentable substrates prior to use in biogas systems to estimate the gas yield. Anaerobic degradation processes are conducted without oxygen. In order to be able to fill the gas room with inert gas above the sample at the start of the test, the measuring bottle is equipped with lateral connection hubs. These connection hubs are sealed with septa, so that carbon dioxide can be removed from the gas room following the anearobic degradation by adding a CO2 absorber. The resulting pressure difference is proportional to the CO2 concentration, the remaining overpressure is proportional to the methane concentration.

The degradation process can be tracked timewise with the operating mode "pressure". The use of special measuring bottles with lateral connection hubs and septa seals allows the interference-free addition of substrates and solutions. As the methane gas production running under anaerobic processes leads to a pressure increase, the measuring range limits may be exceeded. For such cases, it is possible to indicate a "warning pressure" or pressure limit value, so that the user can manipulate the system.

Variations

Model Description Order no.
OxiTop® Control AN 6 6 measuring points for anaerobic measurements 208225
OxiTop® Control AN 12 12 measuring points for anaerobic measurements 208227

Technical Data

OC 110
Measuring range BSB standard and routine 0 to 4000 mg/l BSB
BSB special 0 to 400.000 mg/l BSB
Pressure 500 to 1350 hPa
Data sets (depending on measuring interval) 180 to 360 Datensätze per head
Measuring interval 0.5 h to 99 days
OxiTop®-C/B
Measuring range 500 to 1350 hPa
Accuracy ±1 % v. Mw. ± 1hPa

Accessories

Model Description Order no.
OxiTop® OC 110 Controller 208207
OxiTop®-C/B Measuring head biogas 208831
AK 540/B Interface cable 902842
OxiTop® AD/SK Adapter/screw quiver for GL 45 thread 209016
OxiTop® AD Adapter 209017
OxiTop® SK Screw quivers 209018
MF45/250 Measuring vessel 250 ml 209106
MF45/500 Measuring vessel 500 ml 209107
MF45/1000 Measuring vessel 1000 ml 209108