Spectrophotometer photoLab® 7100 VIS - WTW

Spectrophotometer photoLab® 7100 VIS - WTW

  • SKU: 250203
Request a Quote
  • Description

      Upgrade your photoLab® to reap the rewards!

    All in one - one for all!

    photoLab® 7100 VIS von 320 – 1100 nm offers the unique combination of systematic and spectral analysis in this class of spectrophotometers: Multi-purpose meters for the use from water analysis and wine industry to research and education. Well-proven and liked is the user guidance even for complex tasks. The brilliant HD color display supports menu-guided operations additionally with colored information and messages.

    • Barcode support and automatic cuvette recognition
    • Standard methods such as UVT, SAC, coloration or chlorophyll
    • Multi-level AQA
    • Comprehensive programming opportunities

    Routine at it’s best

    photoLab® 7100 VIS supports fast and affordable routine analysis via barcoded test kits for round and rectangular cuvettes. More than 250 methods are available for waste/drinking water, food & beverage industry as well as production, environmental monitoring or fish farming:

    • Easy to use: place cuvette, read measurement value
    • More than 250 test programs for water analysis, galvanics and general lab analytics
    • Cell and reagent test kits with barcode for automatic program selection
    • Automatic cuvette and measurement range detection for rectangular cuvettes
    • Top reliability due to menu guided comprehensive Analytical Quality Assurance - AQA
    • Measurement “Light” on the road with car battery use
    • USB and Ethernet-connections for easy update, print to PDF or printer, storage and data export

    From Food to Science

    Special procedures for environmental and food parameters such as chlorophyll can be executed handy and clearly arranged due to an excellent menu guidance:

    • Programmed multistep- and multiwavelength methods
    • Comprehensive programming options for user defined requirements
    • Spectra and Kinetics measurements
    • Training of basics and modern photometry in education

    photoLab® color: Color measurement instead of color perception

    Color determination by means of photometric measurement has increased the accuracy and comparability in general compared to subjective perception of visual color measurement procedures. Color measurement is essential for many applications: from water analysis to food & beverage and quality control in production processes. Color values being a quality factor mostly lie within a certain user-specific tolerance range.

    With photoLab® 7000 / 6000 Series and the optional PC-software photoLab® color common measurement procedures can be performed in a handy and neatly arranged way.

    photoLab® Data spectral

    The optional photoLab® Data spectral offers a GLP-compliant and convenient PC-interface to export, store and transfer data.

  • Specifications
    Wavelength Range 320 - 1100 nm
    Optics Monochromator with Grating and step motor / reference beam
    Lamp Wolfram-Halogen 
    Display Farbdisplay 7" backlit
    Bandwidth 4 nm
    Measurement  Concentration, Absorbance, % Transmission, Kinetics and Spectra in Abs or  %Transmission, Multiwavelengths and multistep readings
    Scan speed 700-2000 nm/min,  Scans in 1, 2, 5, 10 nm steps of wavelength range
    Wavelength accuracy/reproduceability ± 1 nm / < 0,5 nm
    Photometric accuracy/reproduceability - 0,003 E for E < 0,600; 0,5% of values for 0,600 < E < 2,000
    Photometric linearity < 1 % for A ≤ 2.000 in the range 340 ... 900 nm
    Straylight < 0,1 %T at 220 nm with NaI, < 0.05 % transmission at 340 and 408 nm with cut-off filter
    Barcode Automatic method recognition including measurement range for all cuvette
    Cuvette 16 mm round, rectangular 10 mm, 20 mm, 50 mm with automatic cell detection for automatic measurement range setting
    Data storage 5000 meausrement values, spectra and kinetics approx. 40 MB => 500 spectra (300-900 nm) and 400 kinetics with 150 measurement values, 
    Methods and Profiles > 250 pre-programmed methods, 1000 user-defined methods, profiles for kinetics and spectra, comprehensive programming options
    Interface / Update 1 USB-A, 1 USB-B, 1 Ethernet / Update via Internet and USB-Stick
    IP Class IP 30 including drainage in optical compartment 
    Power Supply Universal power supply, optional supply via standard adaptor cable for car batteries
    Temperature Range Operation: +10°C bis +35°C, Storage: -25°C bis +65°C
    Weight / Dimensions approx. 4,5 kg / 404 x 197 x 314 (BxHxT)
    Accessories PC software photoLab® Data spectral+photoLab® color, field case, checking tools for AQA

Downloads

  • Manual

    photoLab 7100 VIS (German)

    Photometer,
    Bedienungsanleitung

    photoLab 6x00 / 7x00 (German)

    Photometer,
    Analysenvorschriften

    photoLab Data spectral (German)

    Software PhotoLab Color V200,
    Bedienungsanleitung

    photoLab Color (English)

    Software addition for photometer for color measuring
    Operating manual

    photoLab 7100 VIS (English)

    Photometer
    for newest edition, see German or English version

    photoLab 6x00 / 7x00 (English)

    Photometer
    Analysis instructions

    photoLab Data spectral (English)

    Software for PhotoLab Color V2000,
    Operating manual

    photoLab 7100 VIS (French)

    Photometer,
    for newest edition, see German or English version

    photoLab 6x00 / 7x00 (French)

    Photometer,
    Analysis instructions

    photoLab 7100 VIS (Spanish)

    Photometer,
    for newest edition, see German or English version

    photoLab 6x00 / 7x00 (Spanish)

    Photometer,
    Analysis instructions
  • Flyer

    Upgradeflyer photoLab 6000 7000 (Flyer, English)

    Deckblatt WTW Upgrade Flyer 6000 7000 ENFlyer, 2 Pages
    Upgrade your photoLab® S6/S12 or 6000 to reap the rewards!
    Enjoy the proven simplicity of Use with many new advantages and a brilliant display.

    photoLab 7000 Serie (Flyer, German, 999156D)

    Flyer, 4 Seiten, German, 999156D,
    "Die photoLab Spektralphotometer - photoLab 7100 VIS und photoLab 7600 UV-VIS - Revolutionäre Kombination von Routine- und Spektraler Analytik" 

    photoLab 7000 Series (Flyer, English, 999156US)

    Flyer, 4 Pages, English, 999156US,
    "The photoLab 7000 Series Spectrophotometers - photoLab 7100 VIS and photoLab 7600 UV-VIS - Pioneering combination of routine and spectral analysis" 

    photoLab color Data spectral (Flyer, German, 999178D)

    Flyer, 2 Seiten, German, 999160D,
    "PC-Software für Spektralphotometer der Serien photoLab 7000 und 6000" 

    photoLab color Data spectral (Flyer, English, 999178US)

    Flyer, 2 Pages, English, 999178US,
    "PC software for spectrophotometer series photoLab 7000 and 6000" 

  • Software

    pHotoLab® 6xxx, 7xxx - Update for Software and Programs (Methods) - V2.89 / V2.53 / V2.50

    Please note:
    We recommend to perform the update always via USB memory stick being the most convenient way of doing it.
    Additionally this avoids any potential incompatibilities of Windows operating systems between PC and photoLab® 6000/7000/spectroFlex.
    Software photoLab® 6000 / spectroFlex Software V 2.53
    Software photoLab® 7000 Software V 2.89
    Method Data photoLab® 6000 / 7000/ spectroFlex Method Data V 2.50

    Download and installation notes:

    The download files have been compressed into zip archive (*.zip), eventually accompanied by an additional PDF with important notes.

    Download and installation

    •Store the downloaded file (zip archive) into a directory of your choice
    •Decompress the archive file in a directory of your choice
    •Before installation please read the instruction manual and note the PDF with additional information related to the version.
    •If any problems arise, please contact our customer service personnel: Tel: +49 (0) 881/183-321
    •The revised manuals with analytical description for the new test kits will be available soon.

    Version history – innovations

    2.89 / 2.53 / 2.50:

    • Preparation for connection between photometer and PC via Ethernet- network connection (required for photoLab® color as of V2.00 and photoLab® Data Spectral as of V2.00)

    2.88 / 2.53 / 2.50:

    • Bugfix AQS2 + MatrixCheck for customers with photoLab® 7000

    2.87 / 2.53 / 2.50:

    • Bugfix for the installation for customers with photoLab® 7000 + Brewery Package

    2.85 / 2.53 / 2.49:

    • New program / method #236 for Sulfate
      Second method for Sulfate because of a change in raw material. Please read the instructions. Old methods still available.
    • Optional barcode switch-off
    • Optimization for turbidity programs / methods #64, #82, #103, #150, #154

    2.80 / 2.53 / 2.47:

    Method data/ programs optimized for photoLab® 7000 Series

    • Sulfate 14548
    • Sulfate 00617
    • Sulfate 14564
    • Potassium 14562
    • Potassium 00615

    V2.65 / 2.53 / 2.45:

    -ADMI increase of the measuring range to 1000
    -Optimizations of the method data

    232
    117244
    Cobalt
    New

    233
    117236
    Fluride
    (SPADNS, As frei)
    New

    234
    117243
    Fluoride
    (SPADNS, As frei)
    New

    56
    14848
    Phosphate
    0,005 mg/l – 5.00 mg/l Citation format: PO4-P

    231
    02552
    Tensides, anionic
    Change of citation format

    182
    Susp.solids
    Suspended Solids
    5 – 750 mg/l TSS

    184
    01739
    Manganese

    No longer available
    205
    19250
    Cyanuric acid
    No longer available

    76
    14557
    Fluoride
    No longer available

    V2.52 / 2.52 / 2.31:

    -OptRF: Keeping/Discarding dilution
    -OptRF: Identification (ID) for user calibration
    -OptRF: Active profile shown in display
    -OptRF: Active profile documented with measurement data
    -OptRF: User calibration via context menu
    -Favorites for manual storage ID (photoLab 7x00 only)
    -Language based switch for citation and model description

    V2.40 / 2.40 / 2.30:

    -New: OptRF Calibration profiles allwoing calibration data for several sampling spots
    -OptRF: Entry of more digits for user calibration (particularly Nitrite reference values)
    -Favorit list for last methods used => F3 gives al list of last methods
    -Auto-Store ID allows text entry for several sampling spots with automatic increments for easy ID entry
    -More languages and OptRF completion: Indonesian, Malayan, Corean, Turkish, Russian, Vietnamese
    -New Methods:
    -2530: UVTs with turbditiy correction
    -2531: UVTt w/o turbidity correction
    -2532: SACs with turbditiy correction
    -2533: SACt w/o turbditiy correction
    -2534: SAC436 with turbditiy correction

    photoLab® color - Software V2.00

    ATTENTION: In order for the software to run, the photoLab® 7000 series must be updated to version V2.89 with the conversion to Ethernet.

     New:

    • System requirement is WIN 10
    • Scroll bar for all screen resolutions

Related Products

Close