You are using a version of Internet Explorer (version 8 and / or older) or the compatibility mode, which does not support some functionalities of the site you're viewing. This page can be displayed correctly you therefore may not. In order to use the full functionality of the site is a current Internet Explorer or another browser (eg: Google Chrome, Firefox) necessary.
HomeProductsProduct CatalogLab productsTurbidity > Portable Meters

Portable meters for turbidity measurement

Turbidity measurement in lab quality - from monitoring to the official water control as well as for quality control in the industry with calibration protocol

WTW Portable Turbidimeters
WTW Portable Turbidimeters
_white_ Turb® 430 IR Turb® 430 T photoFlex® Turb Turb® 355 IR Turb® 355 T MultiLine®Multi 3510 IDS MultiLine®Multi 3620 IDS MultiLine®Multi 3630 IDS
Cuvettes round _X_ _X_ _X_ _X_ _X_
Volume > 15 ml _X_ _X_ _X_
Turbidity sensor VisoTurb® 900-P _X_ _X_ _X_
< 1 NTU _X_ _X_ _X_ _X_ _X_ _X_
Lab solution via LabStation _X_ _X_ _X_
Case sets _X_ _X_ _X_ _X_ _X_ _X_
Multi-parameter with photometry and turbidity _X_
Drinking water, nephelometric as per DIN ISO _X_ _X_ _X_ _X_ _X_
Drinking water, nephelometric as per US EPA _X_
Use with depth probes _X_
Wireless Ready _X_ _X_ _X_

Mobile turbidity measurement with lab precision is required for testing by the industry or health offices with uses in surface waters, drinking water preparation and cisterns, well heads and springs. Mobile quality monitoring with lab precision is usable in the lab and the field via the AQS and LabStation.

With the IDS turbidity probe VisoTurb® 900-P, turbidity can be determined in surface waters but also in process applications by means of the portable MultiLine® pocket meters. The VisoTurb® 900-P works at 860 nm at an angle of 90°.

The N.I.S.T. traceable highly precise AMCO Clear® standards are non-toxic and prove to be most accurate and stable against Formazin, which gives them a clear advantage.

Aside from standard procedures, the application is a decisive factor for the choice: Particle size, number and coloration influence of the samples: The table indicates a suitability, but not an absolute must. Colored samples with cell cultures yield very different values, depending on the lamp used, but can both be used in the internal quality control.

Are you interested
in signing up for the free
WTW newsletter?
Newsletter
registration

WTW Newsletter Registration

Any Question?
We advise
you gladly!
Contact

WTW Contact