You are using a version of Internet Explorer (version 8 and / or older) or the compatibility mode, which does not support some functionalities of the site you're viewing. This page can be displayed correctly you therefore may not. In order to use the full functionality of the site is a current Internet Explorer or another browser (eg: Google Chrome, Firefox) necessary.

BOD self check measurement OxiTop ® Control

WTW benchtop meter OxiTop ® Control (6 ea.)
WTW benchtop meter OxiTop ® Control (12 ea.)
WTW's Controller OxiTop® OC 100

Evaluation possibility/data transfer to PC for documentation according to GLP with the respirometric OxiTop® Control meter for BOD self check measurement

  • Convenient operation via controller
  • Suitable for large sample volumes - up to 100 parallel samples
  • Time-saving and error-free with automatic statistical evaluation
  • Simple allocation by automatic sample ID

Complete package for 6 or 12 measuring points for large sample volumes:

This system is the successor of the OxiTop® system. With a practical controller, the OC 100, is has an infrared interface and software-controlled functions: You can start, manage, save and track 100 measuring heads at the same time on a large display, also grouped together. The data can be transferred to the PC for evaluation via the cable AK-540/B and the communications program Achat OC.

For users who have other applications than just BOD, OxiTop® Control S6 / S12 with the OC 110 is the right choice.

Variations

Model Description Order no.
OxiTop®Control 6 Set with 6 measuring points 208201
OxiTop®Control 12 Set with 12 measuring points 208204
OxiTop®-C IS 6 6 measuring points without controller 208130
OxiTop®-C IS 12 12 measuring points without controller 208133
OxiTop®OC 100 Controller 208207

Technical Data

OC 100
Measuring range 0 to 4000 mg/l BSB
Data sets (depending on measuring interval) 180 to 360 data sets per head
Measuring interval 0.5 h to 99 days
OxiTop®-C, OxiTop®-C/B
Measuring range 500 to 1350 hPa
Accuracy ±1 % v. Mw. ± 1hPa

Accessories

Model Description Order no.
OxiTop®-C 6 6 measuring heads 208822
OxiTop®-C 2 2 measuring heads 208823
OxiTop®-C Measuring head 208830
OxiTop®-C/B Measuring head biogas 208831
AK 540/B Interface cable 902842
NHP 600 Sodium hydroxide pads 209140
NTH 600 Nitrification inhibitor 209331
OxiTop® PM Calibration tablets 209333